Product Description
Composed of food-grade-safe
components to help sanitize and maintain your equipment. This is both NSF and
FDA approved.
Product Use
Stera Sheen Green Label Sanitizer is ideal for cleaning and sanitizing your
soft serve equipment. This is also equipped with a milkstone remover which
helps eliminate any harmful milkstone deposits that may accumulate over time,
while still maintaining the integrity of any o-rings and seals inside your
equipment.
Additional Uses
Stera-Sheen Green Label is an EPA
registered Sanitizer approved to clean and sanitize surfaces, including food
contact surfaces. Once properly mixed Stera-Sheen Green Label can be
used to wipe down surfaces such as door knobs, counter tops, tables, etc. Many
customers mix Stera-Sheen Green Label in a Quart spray bottle for an easier
application on surfaces. Below we have included directions for use with
mixing ratios.
Spray Bottle Directions
for Use
Recommended Mixing Ratio: 1 Tablespoon Stera-Sheen Green Label per 1 quart of water. Warm water is recommended. Powder should be full dissolved in water prior
to use.
Cleaning
1. Remove any solids or debris from the surface.
2. Spray as necessary to completely coat the
surface(s) with Stera-Sheen Green Label solution.
3. Brush clean and/or wipe with clean towel until
visibly clean.
Sanitizing
1. Remove any solids or debris from the surface.
2. Spray as necessary to completely coat the
surface with Stera-Sheen Green Label solution.
3. Allow to soak for at least 60 seconds.
4. Use clean towel to remove excess solution or
to dry.
Bucket Directions For
Use
Recommended Mixing Ratio: 1-2 ounces of Stera-Sheen Green Label with 1 gallon of water as
needed
Cleaning
1. Saturate a clean towel or dip a brush in
Stera-Sheen Green Label solution.
2. Brush and/or wipe until surface is visibly
clean.
Sanitizing
1. Using a clean towel completely coat the
surface with Stera-Sheen solution.
2. Allow to soak for at least 60 seconds.
3. Use clean towel to remove excess solution or
to dry.
***Please Note: Spray bottle should be indicated for use with
Stera-Sheen Green Label Sanitizer & Cleaner solution only. Do not use or
mix spray bottle with any other chemicals.
After 4 hours, Stera-Sheen Green Label Sanitizer & Cleaner solution
should be retested to indicate available chlorine per your local health
department requirements, or the solution should be discarded. Mix new solution as needed following the
correct dilution ratio.